<?xml version="1.0"?>
<!-- 2006 (c)CableLabs. All rights reserved -->
<!--PacketCable R2 PACM: XML Schema Definitions for "CL-PKTC-RST-EDVA" -->
<xsd:schema xmlns="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/v1/CL-PKTC-RST-EDVA" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:smi="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/smi" xmlns:SNMPv2-SMI="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-SMI" xmlns:SNMPv2-CONF="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-CONF" xmlns:SNMPv2-TC="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-TC" xmlns:INET-ADDRESS-MIB="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/INET-ADDRESS-MIB" xmlns:CL-PKTC-TC="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/v1/CL-PKTC-TC" xmlns:CLAB-DEF-MIB="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/CLAB-DEF-MIB" xmlns:PKTC-ACLS="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/v1/CL-PKTC-ACL" targetNamespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/v1/CL-PKTC-RST-EDVA" elementFormDefault="qualified" attributeFormDefault="unqualified" xml:lang="en">
 <xsd:annotation>
  <xsd:documentation>
      This XML Schema contains configuration MIB 
      objects for the RST Service Embedded Digital
      Voice Adaptor (E-DVA).  The objects are referenced
      in the PacketCable Residential SIP Telephony (RST)
      E-DVA specification.
    </xsd:documentation>
 </xsd:annotation>
 <xsd:import namespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/smi" schemaLocation="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SMI.xsd"/>
 <xsd:import namespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-SMI" schemaLocation="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-SMI.xsd"/>
 <xsd:import namespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-CONF" schemaLocation="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-CONF.xsd"/>
 <xsd:import namespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-TC" schemaLocation="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/SNMPv2-TC.xsd"/>
 <xsd:import namespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/INET-ADDRESS-MIB" schemaLocation="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/INET-ADDRESS-MIB.xsd"/>
 <xsd:import namespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/v1/CL-PKTC-TC" schemaLocation="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/v1/CL-PKTC-TC.xsd"/>
 <xsd:import namespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/CLAB-DEF-MIB" schemaLocation="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/smi/CLAB-DEF-MIB.xsd"/>
 <xsd:import namespace="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/v1/CL-PKTC-ACL" schemaLocation="http://www.cablelabs.com/namespaces/PacketCable/R2/XSD/v1/CL-PKTC-ACL.xsd"/>
 <xsd:element name="CL-PKTC-RST-EDVA">
  <xsd:annotation>
    <xsd:appinfo>
     <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
    </xsd:appinfo>
  </xsd:annotation>
  <xsd:complexType>
   <xsd:sequence>
    <xsd:element ref="PKTC-ACLS:aggregated-acls" minOccurs="0"/>
    <xsd:element name="pktcPACMRSTEDVAObjects" type="pktcPACMRSTEDVAObjectsType">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcPACMRSTEDVAProfileIDs" type="pktcPACMRSTEDVAProfileIDsType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.2</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVANetDiscProfile" type="pktcRSTEDVANetDiscProfileType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.1</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVAAnsSupProfile" type="pktcRSTEDVAAnsSupProfileType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.2</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVADtmfProfile" type="pktcRSTEDVADtmfProfileType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.3</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVAPrLossProfile" type="pktcRSTEDVAPrLossProfileType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.4</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVADCBiasProfile" type="pktcRSTEDVADCBiasProfileType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.5</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVAMWISignalTypes" type="pktcRSTEDVAMWISignalTypesType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.6</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVACodecProfile" type="pktcRSTEDVACodecProfileType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVATimeProfile" type="pktcRSTEDVATimeProfileType" minOccurs="0">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>unknown</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.8</oid>
       <status>unknown</status>
      </xsd:appinfo>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVANetDiscTableEntry" type="pktcRSTEDVANetDiscTableEntryType" minOccurs="0" maxOccurs="unbounded">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>not-accessible</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.1.1.1</oid>
       <status>current</status>
       <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
       <user-hint>read-only</user-hint>
      </xsd:appinfo>
      <xsd:documentation>
                    Each entry in this data table describes the Network Disconnect
                    Time for the associated line.
                  </xsd:documentation>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVAAnsSupTableEntry" type="pktcRSTEDVAAnsSupTableEntryType" maxOccurs="unbounded">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>not-accessible</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.2.1.1</oid>
       <status>current</status>
       <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
       <user-hint>read-only</user-hint>
      </xsd:appinfo>
      <xsd:documentation>
                    Each entry in this data table describes the Answer Supervision
                    for the associated line.
                  </xsd:documentation>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVAPrLossTableEntry" type="pktcRSTEDVAPrLossTableEntryType" maxOccurs="unbounded">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>not-accessible</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.4.1.1</oid>
       <status>current</status>
       <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
       <user-hint>read-only</user-hint>
      </xsd:appinfo>
      <xsd:documentation>
                    The DVA supports two provisioned loss parameters, one for 
                    the D/A direction (towards the subscriber) and one for A/D 
                    direction (from the subscriber) direction.  This data table 
                    represents the loss for each line provided by the E-DVA.
                    
                    Each entry in this data table describes the loss
                    for the associated line.
                  </xsd:documentation>
     </xsd:annotation>
    </xsd:element>
    <xsd:element name="pktcRSTEDVADCBiasTableEntry" type="pktcRSTEDVADCBiasTableEntryType" maxOccurs="unbounded">
     <xsd:annotation>
      <xsd:appinfo>
       <maxAccess>not-accessible</maxAccess>
       <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.5.1.1</oid>
       <status>current</status>
       <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
       <user-hint>read-only</user-hint>
      </xsd:appinfo>
      <xsd:documentation>
                    DCbias is the signaling method to indicate the Network/E-DVA 
                    in/out of service state. The Operator is able to provision to 
                    enable planned, scheduled service times to not be signaled as 
                    an out of service state pending a maximum duration element. 
                    This data table represents the On Hook In/Out of Service parameters 
                    each line provided by the E-DVA.
                    
                    Each entry in this data table describes the On Hook
                    In/Out of Service parameters for the associated line.
                  </xsd:documentation>
     </xsd:annotation>
    </xsd:element>
   </xsd:sequence>
  </xsd:complexType>
 </xsd:element>
 <xsd:complexType name="pktcPACMRSTEDVAObjectsType">
  <xsd:sequence>
   <xsd:element name="pktcPACMRSTEDVAMinorVersion" type="smi:Integer32" default="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.1</oid>
      <status>current</status>
      <default>0</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>R0</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            The default value of this MIB Object contains the minor version 
            of the data model.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="eXTOBJpktcPACMRSTEDVAObjects" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.4</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcPACMRSTEDVAObjects'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcPACMRSTEDVAProfileIDsType">
  <xsd:sequence>
   <xsd:element name="eXTOBJpktcPACMRSTEDVAProfileIDs" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.2.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcPACMRSTEDVAProfileIDs'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVANetDiscProfileType">
  <xsd:sequence>
   <xsd:element name="eXTOBJpktcRSTEDVANetDiscProfile" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.1.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVANetDiscProfile'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVAAnsSupProfileType">
  <xsd:sequence>
   <xsd:element name="eXTOBJpktcRSTEDVAAnsSupProfile" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.2.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVAAnsSupProfile'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVADtmfProfileType">
  <xsd:sequence>
   <xsd:element name="pktcRSTEDVADtmfRelay" type="SNMPv2-TC:TruthValue" default="true">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.3.1</oid>
      <status>current</status>
      <default>true</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data table represents the DTMF Relay status 
            for each line provided by the E-DVA.
            The E-DVA must support the use of DTMF for both dialed digits 
            and for the relay of digits as part of an established session. 
            When dialing the DTMF, signaling MUST be collected at the E-DVA. 
            The digits are gathered according to the digit map and all digits 
            are sent in a single message. 
            
            If the value of this object is 'true' (on), the E-DVA must offer 
            DTMF relay within SDP upon session origination.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="eXTOBJpktcRSTEDVADtmfProfile" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.3.3</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVADtmfProfile'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVAPrLossProfileType">
  <xsd:sequence>
   <xsd:element name="eXTOBJpktcRSTEDVAPrLossProfile" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.4.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcPACMRSTEDVAObjects'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVADCBiasProfileType">
  <xsd:sequence>
   <xsd:element name="eXTOBJpktcRSTEDVADCBiasProfile" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.5.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVADCBiasProfile'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVAMWISignalTypesType">
  <xsd:sequence>
   <xsd:element name="pktcRSTEDVAMWIToneInd" type="SNMPv2-TC:TruthValue">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.6.1</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This is the MWI Tone Indicator.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVAMWIAncInd" type="SNMPv2-TC:TruthValue">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.6.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This is the MWI Voice Announcement Indication.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVAMWIFSKInd" type="SNMPv2-TC:TruthValue">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.6.3</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This is the MWI FSK Indication.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVAMWIDTMFInd" type="SNMPv2-TC:TruthValue">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.6.4</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This is the MWI DTMF Indication.
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="eXTOBJpktcRSTEDVAMWISignalTypes" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.6.5</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVAMWISignalTypes'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVACodecProfileType">
  <xsd:sequence>
   <xsd:element name="pktcRSTEDVACodecG711Pkt" minOccurs="0" default="20">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7.1</oid>
      <status>current</status>
      <default>20</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the packetization period of a 
            G.711 payload.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:union>
      <xsd:simpleType>
       <xsd:restriction base="smi:Integer32">
        <xsd:minInclusive value="10"/>
        <xsd:maxInclusive value="10"/>
       </xsd:restriction>
      </xsd:simpleType>
      <xsd:simpleType>
       <xsd:restriction base="smi:Integer32">
        <xsd:minInclusive value="20"/>
        <xsd:maxInclusive value="20"/>
       </xsd:restriction>
      </xsd:simpleType>
      <xsd:simpleType>
       <xsd:restriction base="smi:Integer32">
        <xsd:minInclusive value="30"/>
        <xsd:maxInclusive value="30"/>
       </xsd:restriction>
      </xsd:simpleType>
     </xsd:union>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="pktcRSTEDVACodecT38" type="SNMPv2-TC:TruthValue" default="true">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7.2</oid>
      <status>current</status>
      <default>true</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies whether fax relay is enabled/disabled. 
            A value of 'true' (ON) enables fax relay on the E-DVA.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVACodecV152" type="SNMPv2-TC:TruthValue" default="true">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7.3</oid>
      <status>current</status>
      <default>true</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies whether modem relay is enabled/disable.
            A value of 'true' (ON) enables modem relay on the E-DVA.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVACodecPubRepAddrType" type="INET-ADDRESS-MIB:InetAddressType">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7.4</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the domain for the address 
            specified in pktcRSTEDVACodecPubRepAddr.  If the elment 
            pktcRSTEDVACodecPubRepAddr contains a valid IP address, 
            this element MUST be either 'ipv4(1)' or 'ipv6(2)' per 
            RFC3291. 
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVACodecPubRepAddr" type="INET-ADDRESS-MIB:InetAddress">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7.5</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the network address that receives 
            the call statistics report from the E-DVA. Publish reports must
            be sent at the end of each call if enabled.
            
            This address is associated with the domain specified in 
            pktcRSTEDVACodecPubRepAddrType.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVACodecRTCPXR" type="SNMPv2-TC:TruthValue" default="true">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7.6</oid>
      <status>current</status>
      <default>true</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies if extended reports for the sake of voice 
            metrics are included within RTCP packets. A value of 'true' (ON) 
            enables RTCP extended reports.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVACodecRTCPRate" default="5">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7.7</oid>
      <status>current</status>
      <default>5</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the interval at which RTCP packets are 
            sent from the E-DVA. A value of zero for RTCP_RATE disables RTCP 
            transmission.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:restriction base="smi:Integer32">
      <xsd:minInclusive value="0"/>
      <xsd:maxInclusive value="60"/>
     </xsd:restriction>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="eXTOBJpktcRSTEDVACodecProfile" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.7.8</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVACodecProfile'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVATimeProfileType">
  <xsd:sequence>
   <xsd:element name="pktcRSTEDVATimeSync" minOccurs="0" default="48">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.8.1</oid>
      <status>current</status>
      <default>48</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies time synchronization interval.
            A PacketCable E-DVA must support a provisionable network time 
            synchronization interval. The time synchronization interval range 
            must be from 0 to 4320 hours (180 days) in increments of 1 hour. 
            A provisioned value of '0' indicates the E-DVA must NOT execute 
            network time resynchronization. The default network time 
            synchronization interface is 48 hours. 
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:restriction base="smi:Integer32">
      <xsd:minInclusive value="0"/>
      <xsd:maxInclusive value="4320"/>
     </xsd:restriction>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="eXTOBJpktcRSTEDVATimeProfile" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.8.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVATimeProfile'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVANetDiscTableEntryType">
  <xsd:sequence>
   <xsd:element name="pktcRSTEDVANetDisc" minOccurs="0" default="1000">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.1.1.1.1</oid>
      <status>current</status>
      <default>1000</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the time in mSec that the E-DVA
            must remove DC bias when a call has been cleared by the network.
            
            A value of zero (0) indicates that the E-DVA MUST NOT remove DC bias
            when a call disconnects.  The E-DVA MUST implement this element per 
            PKT-SP-RST-E-DVA Section 7.2.3
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:restriction base="smi:Integer32">
      <xsd:minInclusive value="0"/>
      <xsd:maxInclusive value="2000"/>
     </xsd:restriction>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="eXTOBJpktcRSTEDVANetDiscTableEntry" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.1.1.1.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVANetDiscTableEntry'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
  <xsd:attribute name="pktcRSTEDVALineNumber" use="required">
   <xsd:annotation>
    <xsd:appinfo>
     <maxAccess>not-accessible</maxAccess>
     <oid>1.3.6.1.4.1.4491.2.2.7.5.1.2.1</oid>
     <status>current</status>
     <PKTC-ACLS:access-control>AnyWritable</PKTC-ACLS:access-control>
     <user-hint>read-only</user-hint>
    </xsd:appinfo>
    <xsd:documentation>
          This data element MUST identify a Line Number on an E-DVA
        </xsd:documentation>
   </xsd:annotation>
   <xsd:simpleType>
    <xsd:restriction base="smi:Integer32">
     <xsd:minInclusive value="1"/>
     <xsd:maxInclusive value="10"/>
    </xsd:restriction>
   </xsd:simpleType>
  </xsd:attribute>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVAAnsSupTableEntryType">
  <xsd:sequence>
   <xsd:element name="pktcRSTEDVAAnsSup" type="SNMPv2-TC:TruthValue" default="false">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.2.1.1.1</oid>
      <status>current</status>
      <default>false</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the Answer Supervision state.
            Answer Supervision (also called battery reversal, reverse DC bias, 
            or Reverse Loop Current Feed) is signaled when the distant end 
            answers a call originated by the CPE. Typically this signal is 
            used to notify electronic equipment such as PBXs which have a local 
            billing system that a call has been answered. When provisioned to do 
            so, the E-DVA may reverse DC bias when a call has been answered.
            
            The default value for this object is 'false' indicating that 
            Answer Supervision is disabled (off).
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="eXTOBJpktcRSTEDVAAnsSupTableEntry" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.2.1.1.2</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'EDVAAnsSupTableEntry'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
  <xsd:attribute name="pktcRSTEDVALineNumber" use="required">
   <xsd:annotation>
    <xsd:appinfo>
     <maxAccess>not-accessible</maxAccess>
     <oid>1.3.6.1.4.1.4491.2.2.7.5.1.2.1</oid>
     <status>current</status>
     <PKTC-ACLS:access-control>AnyWritable</PKTC-ACLS:access-control>
     <user-hint>read-only</user-hint>
    </xsd:appinfo>
    <xsd:documentation>
          This data element MUST identify a Line Number on an E-DVA
        </xsd:documentation>
   </xsd:annotation>
   <xsd:simpleType>
    <xsd:restriction base="smi:Integer32">
     <xsd:minInclusive value="1"/>
     <xsd:maxInclusive value="10"/>
    </xsd:restriction>
   </xsd:simpleType>
  </xsd:attribute>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVAPrLossTableEntryType">
  <xsd:sequence>
   <xsd:element name="pktcRSTEDVAPrLossDA" minOccurs="0" default="6">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.4.1.1.1</oid>
      <status>current</status>
      <default>6</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the provisioned loss parameter 
            for the D/A direction (towards the subscriber) in dB.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:restriction base="smi:Integer32">
      <xsd:minInclusive value="0"/>
      <xsd:maxInclusive value="12"/>
     </xsd:restriction>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="pktcRSTEDVAPrLossAD" default="6">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.4.1.1.2</oid>
      <status>current</status>
      <default>6</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the provisioned loss parameter 
            for the A/D direction (from the subscriber)in dB.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:restriction base="smi:Integer32">
      <xsd:minInclusive value="0"/>
      <xsd:maxInclusive value="12"/>
     </xsd:restriction>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="eXTOBJpktcRSTEDVAPrLossTableEntry" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.4.1.1.3</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVAPrLossTableEntry'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
  <xsd:attribute name="pktcRSTEDVALineNumber" use="required">
   <xsd:annotation>
    <xsd:appinfo>
     <maxAccess>not-accessible</maxAccess>
     <oid>1.3.6.1.4.1.4491.2.2.7.5.1.2.1</oid>
     <status>current</status>
     <PKTC-ACLS:access-control>AnyWritable</PKTC-ACLS:access-control>
     <user-hint>read-only</user-hint>
    </xsd:appinfo>
    <xsd:documentation>
          This data element MUST identify a Line Number on an E-DVA
        </xsd:documentation>
   </xsd:annotation>
   <xsd:simpleType>
    <xsd:restriction base="smi:Integer32">
     <xsd:minInclusive value="1"/>
     <xsd:maxInclusive value="10"/>
    </xsd:restriction>
   </xsd:simpleType>
  </xsd:attribute>
 </xsd:complexType>
 <xsd:complexType name="pktcRSTEDVADCBiasTableEntryType">
  <xsd:sequence>
   <xsd:element name="pktcRSTEDVADCBiasSig" type="SNMPv2-TC:TruthValue" default="false">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.5.1.1.1</oid>
      <status>current</status>
      <default>false</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element enables/disables the DCbias management per 
            provisioned values on a per telephony port basis. 
            
            A default value of '0'(false)indicates that DCbias must 
            perform per provisioned elements.
            
            A value of '1' (true) indicates that the DCbias is not 
            controlled by the provisioned elements.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:element name="pktcRSTEDVADCBiasMax" default="1200">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.5.1.1.2</oid>
      <status>current</status>
      <default>1200</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the maximum period of time, 
            in seconds, that a DCbias must be maintained following 
            an E-DVA reboot requiring a 'In-Service' State re-establishment.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:restriction base="smi:Integer32">
      <xsd:minInclusive value="0"/>
      <xsd:maxInclusive value="2400"/>
     </xsd:restriction>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="pktcRSTEDVADCBiasHold" default="600">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.5.1.1.3</oid>
      <status>current</status>
      <default>600</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the period of time, in seconds,
            that a DCbias must be maintained following an Out-of-Service 
            State.  If the DCbiasHold duration expires, the DCbias must
            be removed from the telephony port. 
            
            If the Network/E-DVA succeeds to re-establish the 'In-Service' 
            state during the DCbiasHold duration, the DCbiasHold must be 
            cancelled resulting in the DCbias being maintained on the 
            telephony port in support of normal telephony signaling 
            requirements.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:restriction base="smi:Integer32">
      <xsd:minInclusive value="0"/>
      <xsd:maxInclusive value="1200"/>
     </xsd:restriction>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="pktcRSTEDVADCBiasEnable" default="5">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-write</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.5.1.1.4</oid>
      <status>current</status>
      <default>5</default>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>read-only</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            This data element specifies the delay time period prior to 
            reapplying DCbias on the E-DVA telephony port following the 
            re-establishment of the 'In-Service' state following a DCbias 
            removal. This avoids 'race' conditions between the Network/E-DVA 
            transitions from inappropriately signaling to the end user 
            security system.
            
            The E-DVA MUST implement this element per the PacketCable Residential 
            SIP Telephony E-DVA Specification.
          </xsd:documentation>
    </xsd:annotation>
    <xsd:simpleType>
     <xsd:restriction base="smi:Integer32">
      <xsd:minInclusive value="0"/>
      <xsd:maxInclusive value="60"/>
     </xsd:restriction>
    </xsd:simpleType>
   </xsd:element>
   <xsd:element name="eXTOBJpktcRSTEDVADCBiasTableEntry" type="CL-PKTC-TC:PktcPACMExtension" minOccurs="0">
    <xsd:annotation>
     <xsd:appinfo>
      <maxAccess>read-only</maxAccess>
      <oid>1.3.6.1.4.1.4491.2.2.7.5.1.3.5.1.1.5</oid>
      <status>current</status>
      <PKTC-ACLS:access-control>NetworkWritable</PKTC-ACLS:access-control>
      <user-hint>RW</user-hint>
     </xsd:appinfo>
     <xsd:documentation>
            Extension object for 'pktcRSTEDVADCBiasTableEntry'.
          </xsd:documentation>
    </xsd:annotation>
   </xsd:element>
   <xsd:any namespace="##other" processContents="lax" minOccurs="0" maxOccurs="unbounded"/>
  </xsd:sequence>
  <xsd:attribute name="pktcRSTEDVALineNumber" use="required">
   <xsd:annotation>
    <xsd:appinfo>
     <maxAccess>not-accessible</maxAccess>
     <oid>1.3.6.1.4.1.4491.2.2.7.5.1.2.1</oid>
     <status>current</status>
     <PKTC-ACLS:access-control>AnyWritable</PKTC-ACLS:access-control>
     <user-hint>read-only</user-hint>
    </xsd:appinfo>
    <xsd:documentation>
          This data element MUST identify a Line Number on an E-DVA
        </xsd:documentation>
   </xsd:annotation>
   <xsd:simpleType>
    <xsd:restriction base="smi:Integer32">
     <xsd:minInclusive value="1"/>
     <xsd:maxInclusive value="10"/>
    </xsd:restriction>
   </xsd:simpleType>
  </xsd:attribute>
 </xsd:complexType>
</xsd:schema>


